Seitenansicht 3
EXAMPLE OF A PRIVATE OFFICE WITH
SUSPENDED LUMINAIRE WITH SENSOR
Suspended Alera Lighting Luminaire
12-18" Suspension
8' Mounting Height from Floor to Sensor
2.5' from Floor to Desktop
Aircraft Cable Feed Cord
76
BALLAST
EDUMK7
Universal Voltage
Electronic Dimming
Advance Mark 7 (0-
10V)
3, 4
EDULUTES
Universal Voltage
Electronic Dimming
Lutron EcoSystem
(EC5 Series)
4,7
3
Philips Mark 7 required with DSPL Option.
Contact factory for other compatible Philips ballasts.
4
Not available with all configurations; some limitations apply.
Contact factory for details.
7
Lutron EcoSystem series ballast required for DSL option.
Contact factory for other compatible Lutron ballasts.
OPTIONS
DSPL
Philips LuxSense
Daylight Sensor
3, 4
DSL
Lutron Daylight Sensor
(Must Specify Lutron
Dimming Ballast)
4, 7
STEP 3 PLACE ORDER
Example shown below is Curv Radial Baffle product.
For additional product availability, see back cover or contact Alera Lighting for additional details.
STEP 4 DESIGN ROOM
Examples below show installed sensor locations. Products will be wired to your specifications.
Single 4', 8' or 12'
* Fixture with Sensor.
Row of two or more 4', 8' or 12'
* Fixtures with Sensors where Sensor is placed at row end.
Row of two or more 4', 8' or 12'
* Fixtures with Sensors where Sensor is placed within row.
*Available lengths vary by product family.
Short rows typically require a single feed where control wiring is carried through the
luminaires via quick-connect wiring to dramatically reduce complexity and on-site wiring
errors. Power feed wires are also handled via the installer-friendly Quick-Connect method.
QUICK-CONNECT IN-ROW CONTROL AND FIXTURE WIRING
Product becomes an element of the EcoSystem family and the installed sensor is commissioned using Lutron's
proprietary interfaces. Ballast and sensor are pre-installed by Alera to facilitate on-site simplicity of sensor installation
and connection to ballast(s). For details, see pages 6 and 7 of this brochure.
DSL OPTION LUTRON ECOSYSTEM® SENSOR
System is pre-commissioned by Philips and assumes 45fc out-of-the-box. For on-site adjustments, if desired, simply
twist sensor to set at new level. For details, see page 9 of this brochure.
DSPL OPTION PHILIPS LUXSENSE
STEP 5 EASY INSTALL
Sensors arrive pre-installed
5 STEPS TO DAYLIGHTING SUCCESS